For technical advice, equipment and application support, call 408.898.2215
Buy or Rent. Request a Quote.
CMP-200
Digital Clamp-on AC leakage current meter
Description
Technical specification
Files
  • Description
    The CMP-200 digital clamp meter has been designed for clamp measurements of AC leakage current.
    AC current measurement up to 200 A.
    • high resolution (0.1 mA),
    • three measuring ranges: 200 mA, 2 A, 200 A.
    The most important features of CMP-200 are:
    • display LCD 3½ digits (max 1,999),
    • white LED backlight,
    • internal diameter clamp approx. 30 mm (1.2"),
    • DATA HOLD function, for holding measured values.
    • MAX function,
    • AUTO-OFF function,
    • double molded casing.
  • Technical specification

    The CMP-200 digital clamp meter has been designed for clamp measurements of AC leakage current.
    AC current measurement up to 200 A.

    • high resolution (0.1 mA),
    • three measuring ranges: 200 mA, 2 A, 200 A.

    The most important features of CMP-200 are:

    • display LCD 3½ digits (max 1,999),
    • white LED backlight,
    • internal diameter clamp approx. 30 mm (1.2”),
    • „DATA HOLD” function, for holding measured values.
    • „MAX” function,
    • „AUTO-OFF” function,
    • double molded casing.

    AC current measurement

    Range Resolution Accuracy
    199.9 mA 0.1 mA ±(5% m.v + 8 dgt)
    1.999 A 0.001 A ±(5% m.v. + 10 dgt)
    199.9 A 0.1 A ±(2.5% m.v. + 10 dgt)

     

    „m.v.”- measured value

    Electric security:

    • type of insulation: double, according to EN 61010 - 1 and IEC 61557
    • measurement category: CAT II 600 V acc. to EN 61010 - 1:2004
    • protection class acc. to EN 60529: IP40

    Other technical data:

    • power supply: 1.5 V AAA battery (2 pcs.)
    • over range indication: 0L displayed
    • sampling rate: 2 times per second
    • display: 1,999 counts LCD, 3½ digits
    • dimensions: 7.2" x 2.4" x 1.3" / 182 x 61 x 34 mm
    • weight (including batteries): 0.56 lbs / 225 g
    • auto power OFF: 15 min.
    • accordance with following standards: EN 61010 - 1:2004, EN 61010 - 2 - 032
    • quality standard: ISO 9001

    Rated operational conditions:

    • operating temperature and humidity: 32 F to 86 F / 0 to +30°C (max 90%), 86 F to 104 F / 30 to 40°C (max 75%), 104 F to 122 F / 40 to 50°C (max 45%)
    • storage temperature: -13 F to 140 F / -25 to +60°C max <90%
    • operating altitude: max 9,843 ft / 3,000 m
  • Files

Optional accessories