CMP-1006
Digital Clamp-on multimeter
Description
Technical specification
Files
  • Description

    (TRUE RMS) up to 1000 A.

    Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

    AC/DC voltage measurement (TRUE RMS) up to 600 V.

    Resistance measurement and continuity test:

    • continuity test with acoustic signalling (beeper) for resistance below 40.

    Temperature measurement (Fahrenheit and Celsius units).

    Frequency measurement.

    Duty cycle measurement.

    Diode test.

    Additionally:

    • safe, insulated measuring clamps,
    • autoranging/manual range selection,
    • DATA HOLD function, for holding measured values,
    • backlit LCD,
    • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
    • MAX/MIN function,
    • over range indication,
    • AUTO-OFF function.
  • Technical specification

     

    Electric security:

    • measurement category: CAT III 600 V acc. to EN 61010-1:2004
    • protection class acc. to EN 60529: IP40


    Other technical data:

    • power supply: 9 V battery type 6LR61
    • display: 6,600 counts, backlit LCD
    • continuity test: threshold 40 Ω; test current < 0.5 mA
    • diode test: test current of 0.3 mA, typical open circuit voltage < 3 V DC, typical
    • low battery indication: BAT displayed
    • over range indication: 0L displayed
    • sampling rate: 2 times per second
    • INRUSH: integration time 100 ms
    • temperature sensor: type K thermocouple
    • input impedance: 10 MΩ (V DC and V AC)
    • AC bandwidth: 50 to 400 Hz (A AC and V AC)
    • auto power OFF: approx. 25 min
    • dimensions: 9" x 3.1" x 2" / 229 x 80 x 49 mm
    • weight: 0.67 lbs / 303 g
    • accordance with following standards: EN 61010-1:2004, EN 61010-2-032
    • quality standard: ISO 9001

    Rated operational conditions:

     

    • internal clamp diameters: d1 = 1.4" / 36 mm / d2 = 2" / 52 mm
    • operating temperature: 41°F to 104°F / +5 to +40°C
    • storage temperature: -4°F to 140°F / -20 to +60°C
    • operating humidity: max 80% up to 88°F (31°C) decreasing linearly to 50% at 104°F (40°C)
    • storage humidity: <80%
    • operating altitude: max 6562 ft / 2000 m

     

    AC/DC current measurement (TRUE RMS)

    Range Resolution Accuracy
    (DC)
    Accuracy
    (AC)
    0 to 659.9 A 0.1 A ±(2.5% m.v. +5 dgt) ±(2.5% m.v + 8 dgt)
    for f=50 to 60 Hz
    660 to 1,000 A 1 A ±(2.8% m.v. +8 dgt) ±(2.8% m.v. + 8 dgt)
    for f=50 to 60 Hz

     

     

    DC voltage measurement 

    Range Resolution Accuracy
    0 to 6.599 V 0.001 V ±(1.5% m.v. + 3 dgt)
    6.60 to 65.99 V 0.01 V
    66.0 to 600.0 V 0.1 V


    AC voltage measurement (TRUE RMS)

    Range Resolution Accuracy
    0 to 6.599 V 0.001 V ±(1.8% m.v. + 5 dgt)
    for f=50 to 60 Hz
    6.60 to 65.99 V 0.01 V
    66.0 to 600.0 V 0.1 V

    Resistance measurement

    Range Resolution Accuracy
    0.0 to 659.9 Ω 0.1 Ω ±(1.0% m.v. + 4 dgt)
    0.660 to 6.599 kΩ 0.001 kΩ ±(1.5% m.v. + 2 dgt)
    6.60 to 65.99 kΩ 0.01 kΩ
    66.0 to 659.9 kΩ 0.1 kΩ
    0.660 to 6.599 MΩ 0.001 MΩ ±(2.5% m.v. + 3 dgt)
    6.60 to 66.00 MΩ 0.01 MΩ ±(3.5% m.v. + 5 dgt)

     

    Frequency measurement

    Range Resolution Accuracy
    30.0 to 999.9 Hz 0.1 Hz ±(1.2% m.v. + 2 dgt)
    sensitivity:30 to 5 kHz:10 Vrms min.
    5 kHz to 15 kHz:40 Vrms min.
    for 20% to 80% duty cycle
    1.000 to 9.999 kHz 0.001 kHz
    10.00 to 15.00 kHz 0.01 kHz

     

    Temperature measurement

    Range Resolution Accuracy
    -20 to 760°C 0.1°C ±(3.0% m.v. + 5°C)
    -4 to 1400°F 0.1°F ±(3.0% m.v. + 9°F)

    Duty cycle measurement

    Range Resolution Accuracy
    10.0 to 94.9% 0.1% ±(1.2% m.v. + 2 dgt)

     

    • pulse width: 100μs to 100 ms
    • frequency range: 30 Hz to 5 kHz
    • sensitivity: 30 Hz to 5 kHz: 10 Vrms, 5 kHz to 15 kHz: 40 Vrms

    „m.v.”- measured value

     