MIC-5010 5kV Class Insulation Tester
Insulation Resistance meter
Price: $2600
Description
Technical specification
Files
  • Description

    The MIC-5010 is a portable, rugged, easy-to-use, 5 kV class insulation test meter.  The MIC-5010 has a wide measurement range, selectable test voltages, and excellent safety features.

    Insulation resistance measurement features:

    • User-selectable test voltage any from 50 to 1,000 V (with 10 V resolution) and 1,000 to 5,000 V (with 25 V resolution)
    • Continuous indication of measured insulation resistance or leakage current
    • Audio beeps every five-second periods to indicate measurement progress
    • Indication of actual test voltage during measurement
    • 1.2 mA and 3 mA test current
    • Step voltage insulation resistance measurement (SV)
    • Selectable test times (T1, T2 , T3 from 1 to 600 seconds) to measure one or two absorption coefficients
    • Adjustable measuring time to 99' 59'’
    • Polarization index (PI) and dielectric absorption ratio (DAR) measurements
    • Dielectric Discharge calculation (DD)
    • High-noise immunity; digital filters function for measurements in high noise enviroment (10 s, 30 s , 60 s)
    • Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4
    • Adjustable limits for measured resistance RISO and RCONT.
    • Measurement of capacitance during the measurement of RISO
    • DC and AC voltage measurement in the range of 0 to 600 V
    • Meter conforms to EN 61557

    Safety First Features.

    • CAT-IV 600V, CAT-III 1000V
    • Automatic discharge of tested object after the insulation resistance measurement completes to remove high-voltage charge remaining due to cable capacitance
    • Protection against measuring live objects, measurement will not proceed
    • Measurements with test leads up to 66 ft / 20 m length

    Construction

    • Backlit keyboard and display
    • Rugged IP 54 case - Protected from water spray from any direction

    Power Supply

    • Power supply from battery packs, low battery warning indicator, built-in fast charger

    Memory Features

    • 990 cells of memory (11,880 records) to save test results
    • Data transmission to a PC via USB cable

     Press article: MIC-10k1, MIC-5050: new models of insulation resistance meters.

     

    Test drive the MIC 5010 with this Online Simulator:

     

    There is also an offline simulator of MIC 5010 ready to download in the Files section.

  • Technical specification

    Insulation resistance measurement (two-lead)

    Measurement range acc. to IEC 61557-2: 50k to 15.0 TΩ (IISOnom = 1.2 mA or 3 mA)

    Range Resolution Accuracy
    0.0 to 999 kΩ 1 kΩ ±(3% m.v. + 10 digits)
    1.00 to 9.99 MΩ 0.01 MΩ
    10.0 to 99.9 MΩ 0.1 MΩ
    100 to 999 MΩ 1 MΩ
    1.00 to 9.99 GΩ 0.01 GΩ
    10.0 to 99.9 GΩ 0.1 GΩ
    100 to 999 GΩ 1 GΩ ±(3.5% m.v. + 10 digits)
    1.00 to 9.99 TΩ 0.01 TΩ ±(7.5% m.v. + 10 digits)
    10.0 to 15.0 TΩ 0.1 TΩ ±(10% m.v. + 10 digits)

    Values of measured resistance depending on measurement voltage

    Voltage UISO Measurement range
    250 V 500 GΩ
    500 V 1.00 TΩ
    1,000 V 2.00 TΩ
    2,500V 5.00 TΩ
    5,000V 15.0 TΩ

     

    Measurement of leakage current

     

    Range Resolution Accuracy
    0 to ILmax m, µ, n [A] Calculated basing on
    resistance measurements

    · ILmax – maximum current at short circuit of leads,
    · resolution and units result from the measurement range of individual insulation resistance.

    Step voltage insulation resistance measurement

    Target voltage Measurement
    voltage sequence
    1 kV 200, 400, 600, 800, 1,000 V
    2.5 kV 0.5, 1, 1.5, 2, 2.5 kV
    5 kV 1, 2, 3, 4, 5 kV

    · duration of each "step" adjustable from 30s to 5mins
    · measurement result for each voltage step is stored in memory

    Continuity measurement of protective connections and equipotential bonding with 200 mA current
    Measurement range acc. to EN 61557-4: 0.12 to 999 Ω

    Range Resolution Accuracy
    0.00 to 19.99 Ω 0.01 Ω ±(2% m.v. + 3 digits)
    120.0 to 199.9 Ω 0.1 Ω
    200 to 999 Ω 1 Ω ±(4% m.v. + 3 digits)
    · Voltage on open terminals: 4 to 24 V
    · Output current at R < 2 Ω: Imin > 200 mA (ISC: 200 to 250 mA)
    · Compensation of test lead resistance
    · Current flowing in both directions, mean value of resistance is displayed

    Capacity measurement

    Range Resolution Accuracy
    1 to 999 nF 1 nF ±(5% m.v. + 5 digits)
    1.00 to 49.99 µF 0.01 µF

    · Capacity measurement result is displayed after the RISO measurement

    DC and AC voltage measurement

    Range Resolution Accuracy
    0.0 to 29.9 V 0.1 V ±(2% m.v. + 20 digits)
    30.0 to 299.9 V 0.1 V ±(2% m.v. + 6 digits)
    300 to 600 V 1 V ±(2% m.v. + 2 digits)
     

    The acronym “m.v.” stands for a “measured reference value”.