For technical advice, equipment and application support, call 408.898.2215
Buy or Rent. Request a Quote.
MIC-10 1kV Class Insulation Tester
Insulation Resistance Meter
Price: $525
Description
Technical specification
Files
  • Description

    The MIC-10 is a hand-held, rugged, easy-to-use, 1 kV class insulation test meter.  The MIC-10 has a wide measurement range, selectable test voltages, and excellent safety features.

    • Insulation resistance measurement to 10 GΩ
    • User selected test voltages: 50, 100, 250, 500, 1000 V
    • Displays continuous indication of insulation resistance
    • Audio beeps every five-second periods to indicate measurement progress
    • Indication of actual test voltage during the measurement
    • Three-lead measurement
    • Continuity measurement of protective and equipotential conductors according to EN 61557-4
    • Low-voltage circuit continuity and resistance measurement:
    • Circuit resistance measurement (<1999 Ω)
    • Audio alert signal if circuit resistance is below 30 Ω
    • Capacitance measurement during the RISO measurement
    • Measurement of alternating and direct voltages from 0 to 600 V
    • Meter conforms to EN 61557

    Safety First Features.

    • Automatic discharge of tested object after the insulation resistance measurement completes to remove high voltage charge remaining due to cable capacitance
    • Protection against measuring live objects, measurement will not proceed

    Power Supply

    • 4 AA disposable or rechargeable batteries
    • Indicates state of battery charge
  • Technical specification

    Electric safety:

    • type of insulation: double, according to EN 61010 - 1 and IEC 61557
    • measurement category: IV 600 V (III 1000 V) according to EN 61010 - 1
    • protection class acc. to EN 60529: IP67

    Other technical specifications:

    • power supply: 44 AA disposable or rechargeable batteries or battery package Ni-MH
    • weight: ~2.2 lbs / ~1 kg 
    • dimensions: 8.7" x 4" x 2.4" / 220 x 100 x 60 mm, 

    Insulation resistance measurement

    Measuring range according to EN 61557 - 2 for VN=50 V: 50 kΩ to 250.0 MΩ

    Range Resolution Accuracy
    0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 8 digits)
    1.000 to 9.999 MΩ 0.001 MΩ
    10.0 to 99.99 MΩ 0.01 MΩ
    100.0 to 250.0 MΩ 0.1 MΩ

    Measuring range according to EN 61557 - 2 for VN=100 V: 100 kΩ to 500.0 MΩ

    Range Resolution Accuracy
    0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 8 digits)
    1.000 to 9.999 MΩ 0.001 MΩ
    10.0 to 99.99 MΩ 0.01 MΩ
    100.0 to 500.0 MΩ 0.1 MΩ


    Measuring range according to EN 61557 - 2 for UN=250 V: 250 kΩ to 2.000 GΩ

    Range Resolution Accuracy
    0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 8 digits)

    1.000 to 9.999 MΩ

    0.001 MΩ

    10.0 to 99.99 MΩ

    0.01 MΩ
    100.0 to 999.0 MΩ 0.1 MΩ
    1.000 to 2.000 GΩ 0.001 GΩ

    Measuring range according to PN-EN 61557 - 2 for UN=500 V: 500 kΩ to 5.00 GΩ

    Range Resolution Accuracy
    0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 8 digits)
    1.000 to 9.999 MΩ 0.001 MΩ
    10.00 to 99.99 MΩ 0.01 MΩ
    100.0 to 999.0 MΩ 0.1 MΩ
    1.000 to 5.000 GΩ 0.001 GΩ ±(4% m.v. + 6 digits)


    Measuring range according to EN 61557 - 2 for UN=1000 V: 1,000 kΩ to 10.00 GΩ

    Range Resolution Accuracy
    0.0 to 999.9 kΩ 0.1 kΩ ±(3% m.v. + 8 digits)
    1.000 to 9.999 MΩ 0.001 MΩ
    10.00 to 99.99 MΩ 0.01 MΩ
    100.0 to 999.0 MΩ 0.1 MΩ
    1.000 to 5.000 GΩ 0.001 GΩ ±(4% m.v. + 6 digits)
    5.00 to 10.00 GΩ 0.01 GΩ

    Continuity measurement of protective and equipotential conductors with the 200 mA current

    Measuring range according to EN 61557 - 4: 0.10 to 1,999 Ω

    Range Resolution Accuracy
    0.00 to 19.99 Ω 0.01 Ω ±(2% m.v. + 3 digits)
    20.0 to 199.9 Ω 0.1 Ω
    200 to 1999 Ω 1 Ω

    ±(4% m.v. + 3 digits)

    • Voltage on open terminals: <8 V
    • Output current at R <2 Ω: ISC >200 mA: ISC >200 mA
    • Compensation of test leads’ resistance
    • Unidirectional current flow

    Low-voltage and resistance measurement

    Range Resolution Accuracy
    0.0 to 199.9 Ω 0.1 Ω ±(3% m.v. + 3 digits)
    200 to 1999 Ω 1 Ω
    • Voltage on open terminals: <8 V
    • Current for closed terminals 5 mA < ISC < 15 mA
    • Sound signal and green LED on when measured resistance < 30 Ω ± 50%
    • Compensation of test leads’ resistance,

    Capacitance measurements

    Range Resolution Accuracy
    1 to 999 nF 1 nF ±(5% m.v. + 5 digits)
    1.00 to 9.99µF 0.01µF
    • Capacitance value displayed during the RISO measurement
    • For test voltages below 100 V and measured resistance below 10 MΩ, unspecified capacitance measurement error

    Measurement of alternating and direct voltage

    Range Resolution Accuracy
    0.0 to 299.9 V 0.1 V ±(2% m.v. + 6 digits)
    300 to 600 V 1 V ±(2% m.v. + 2 digits)
    • Frequency range: 45 to 65 Hz