For technical advice, equipment and application support, call 408.898.2215
Buy or Rent. Request a Quote.
MIC-05s1 5 kV Class Insulation Tester
Insulation Resistance Meter 5kV
Price: $3405
3 meter test leads are standard. Extra long test leads are available.
Description
Technical specification
Files
  • Description

     The MIC-05s1 is a portable, rugged, easy-to-use, 5 kV class insulation test meter. 

    The MIC-5s1 has a wide measurement range, selectable test voltages, and excellent safety features.

    Insulation resistance measurement features to 20.0 TΩ:

    • User-selectable test voltage any from 50 to 1,000 V (with 10 V resolution) and 1,000 to 5,000 V (with 25 V  resolution)
    • Continuous indication of measured insulation resistance or leakage current
    • Audio beeps every five-second periods to indicate measurement progress
    • Indication of actual test voltage during measurement
    • 1.2 mA, 3 mA and 5 mA test current
    • Step voltage and ramp voltage insulation resistance measurements (SV) (RV)
    • Selectable test times (T1, T2 , T3 from 1 to 600 seconds) to measure one or two absorption coefficients
    • Adjustable measuring time to 99' 59'’
    • Polarization index (PI) and dielectric absorption ratio (DAR) measurements
    • Dielectric Discharge calculation (DD)
    • High-noise immunity; digital filters function for measurements in high noise environment (10 s, 30 s , 60 s)
    • Adjustable limits for measured resistance RISO.
    • Measurement of capacitance during the measurement of RISO
    • DC and AC voltage measurement in the range of 0 to 600 V
    • Meter conforms to EN 61557

    Safety First Features.

    • CAT-IV 600V, CAT-III 1000V
    • Automatic discharge of tested object after the insulation resistance measurement completes to remove high voltage charge remaining due to cable capacitance
    • Protection against measuring live objects, measurement will not proceed
    • Measurements with test leads up to 65 ft / 20 m length

    Construction

    • Backlit keyboard and graphical display
    • Rugged IP 54 case - protected from water spray from any direction

    Power Supply:

    • Bult-in battery pack, low battery warning indicator, built-in fast charger
    • AC power: 90 V to 260 V, 50 Hz / 60 HzGraphical display

    Memory:

    • 990 cells of memory (11,880 records) to save test results
    • Wireless data transmission to a PC with Bluetooth®, or via USB cable

    Power Supply

    • Battery packs, low battery warning indicator, built-in fast charger
    • Electric grid 90 V to 260 V, 50 Hz / 60 Hz

    Memory Features

    • 990 cells of memory (11880 records) to save test results
    • Wireless data transmission to a PC with Bluetooth®, or via USB cable

    Press article: Sonel introduces new models of insulation resistance meters.

     

     

     

     

  • Technical specification

    Insultaion Resistance Measurement

    Measurement range acc. to IEC 61557-2: VN = 5000V: 5.00MΩ to 20.0TΩ

    Measurement with DC and increasing voltage (SV) for UISO = 5 kV

    Range Resolution Accuracy
    0.0 to 999 kΩ 1 kΩ ±(3% m.v. + 10 digits)
    1.00 to 9.99 MΩ 0.01 MΩ
    10.0 to 99.9 MΩ 0.1 MΩ
    100 to 999 MΩ 1 MΩ
    1.00 to 9.99 GΩ 0.01 GΩ
    10.0 to 99.9 GΩ 0.1 GΩ
    100 to 999 GΩ 1 GΩ ±(3.5% m.v. + 10 digits)
    1.00 to 9.99 TΩ 0.01 TΩ ±(7.5% m.v. + 10 digits)
    10.0 to 20.0 TΩ 0.1 TΩ ±(12.5% m.v. + 10 digits)
     

    Approximate maximum values of the measured resistance, depending on the test voltage

    Voltage VISO Measurement range Measurement range with AutoISO-5000
    50 V 200 GΩ 20.0 GΩ
    100 V 400 GΩ 40.0 GΩ
    250 V 1.00 TΩ 100 GΩ
    500 V 2.00 TΩ 200 GΩ
    1000 V 4.00 TΩ 400 GΩ
    2500 V 10.00 TΩ 400 GΩ
    5000 V 20.0 TΩ 400 GΩ
         


    AC/DC voltage measurement

    Range Resolution Accuracy
    0.0 to 29,9 V 0.1 V ±(2% m.v. + 20 digits)
    30.0 to  299.9 V 0.1 V ±(2% m.v. + 6 digits)
    300 to 750 V 1 V ±(2% m.v. + 2 digits)
    • Frequency range: 45 to 65Hz
    Capacitance measurement 
    Display range Resolution Accuracy
    1 to 999 nF 1 nF ±(5% m.v. + 5 digits)
    1.00 to 49.99 µF 0.01 µF
    • Measurement of capacitance is available only during RISO measurement (when discharging the object).
    • Accuracy of measurement is met for tested capacitance connected in parallel with a resistance greater than 10 MΩ
    • For measurement voltages below 100 V accuracy is not specified

    Temperature measurement 

    Display range Resolution Accuracy
    -40.0 to 99.9 °C 1 °C ±(3% m.v. + 8 digits)
    -40,0 to 211,8 °F 1 °F ±(3% m.v. + 16 digits)

    Electric security

    • type of insulation: double, according to EN 61010-1 and IEC 61557
    • measurement category: IV 600 V (III 1000 V) according to EN 61010-1
    • protection class acc. to EN 60529: IP40 (IP67 with closed cover)

    Other technical data

    • Power supply from: battery 12V or from electric grid 90 V to 260 V, 50 Hz / 60 Hz
    • weight: ca. 15.5 lbs / 7 kg
    • dimensions: 15.35" x 12.2" x 7.09" / 390 x 310 x 180 mm
    • display: LCD 5,6'’ graphical
    • data transmission: USB cable or Bluetooth®

    The acronym “m.v.” stands for a “measured reference value”.

  • Files