    A variety of functions are all at your fingertips in a hand-held device.

    Measures current up to 2,000 A; the large jaw is 2.4 ins diameter, and it can clamp around bus bars 2.75 x 0.7 ins.

    Safety First!

    CAT IV 600 V measurement category.

    The instrument has an electronic overload protection of all functions and ranges.

    Features:

    • AC current measurement (TRUE RMS) up to 1,500 Amps and DC up to 2,000 Amps.
    • Measurement of INRUSH current for start-up of electrical motors or equipment.
    • AC voltage measurement (TRUE RMS) up to 750 VAC and DC up to 1,000 VDC.
    • Resistance measurement for resistances below 30 Ω
    • Continuity test with audio.
    • Capacitance measurement.
    • Temperature measurement (Fahrenheit or Celsius).
    • Frequency measurement.
    • Duty cycle measurement.
    • Diode test.
  • Technical specification

    AC current measurement (TRUE RMS) up to 1,500 A and DC up to 2,000 A.

    Measurement of INRUSH current in start-up phase of electrical device.

    AC voltage measurement (TRUE RMS) up to 750 V and DC up to 1,000 V.

    Resistance measurement and continuity test:

    • continuity test with acoustic signalling (beeper) for resistance below 30 Ω.

    Capacitance measurement

    Temperature measurement (Fahrenheit or Celsius).

    Frequency measurement.

    Duty cycle measurement.

    Diode test.

    Additionally:

    • safe, insulated measuring clamp,
    • autoranging,
    • „DATA HOLD” function, for holding measured values,
    • backlit LCD,
    • „DC ZERO” mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored „zero” value,
    • „MAX/MIN” function,
    • over range indication,
    • „AUTO-OFF” function after 30 min.

    Electric security:

    • measurement category: CAT IV 600 V acc. to EN 61010 - 1,
    • protection class acc. to EN 60529: IP20,

    Other technical data:

    • power supply, 9 V battery type 6LR61,
    • display: 6,600 counts, backlit LCD,
    • continuity test: threshold 30 Ω,
    • diode test: test current of 0.8 mA , typical open circuit voltage 3.2 V DC, typical,
    • low battery indication: BAT displayed,
    • over range indication: ‘OL’ displayed,
    • temperature sensor: type K thermocouple,
    • input impedance: ca.10 MΩ (V DC and V AC),
    • AC bandwidth: 50 to 500 Hz,
    • auto power OFF: 30 minutes,
    • dimensions: 11" x 4.25" x 2.09" / 281 x 108 x 53 mm,
    • weight: 1.26 lbs / 570 g (with battery),
    • accordance with following standards: EN 61010 - 1, EN 61010 - 2-032.

    Rated operational conditions:

    • able to open the clamp: Ø 2.25" / 57 mm wire; 2.75" x 0.7" / 70 x 18 mm bus bar,
    • operating temperature: 32F to 122F / 0 to +50 °C,
    • storage temperature: -4F to 140F / -20 to +60 °C,
    • operating altitude: max 6,562 ft / 2,000 m.

     

    DC current measurement

    Range Resolution Accuracy
    0.0 to 659.9 A 0.1 A ±(2.0% m.v. + 5 digits)
    660 to 2000 A 1 A ±(3.0% m.v. + 5 digits) for 660 to 1000 A
    ±(5.0% m.v. + 5 digits) for 1000 to 2000 A

    AC current measurement (TRUE RMS)

    Range Resolution Accuracy
    0.0 to 659.9 A 0.1 A ±(2.0% m.v. + 10 digits) for 50 to 60 Hz
    ±(3.0% m.v. + 10 digits) for 61 to 400 Hz
    660 to 1,500 A 1 A ±(2.5% m.v. + 10 digits) for 50 to 60 Hz
    and 660 to 1000 A
    ±(3.5% m.v. + 10 digits) for 61 to 400 Hz
    and 660 to 1000 A
    ±(5.0% m.v. + 10 digits) for 50 to 400 Hz
    and 1000 to 1500

    DC voltage measurement

    Range Resolution Accuracy
    0.000 to 6.599 V 0.001 V ±(0.5% m.v. + 2 digits)
    6.60 to 65.99 V 0.01 V
    66.0 to 659.9 V 0.1 V
    660 to 1,000 V 1 V

    AC voltage measurement (true RMS)

     

    Range Resolution Accuracy
    0.000 to 6.599 V 0.001 V ±(1.5% m.v. + 8 digits)
    for 50 to 500 Hz
    6.60 to 65.99 V 0.01 V
    66.0 to 659.9 V 0.1 V
    660 to 750 V 1

    Resistance measurement

    Range Resolution Accuracy
    0.0 to 659.9 Ω 0.1 Ω ±(1.0% m.v. + 5 digits)
    0.660 to 6.599 kΩ 0.001 kΩ
    6.60 to 65.99 kΩ 0.01 kΩ
    66.0 to 659.9 kΩ 0.1 kΩ
    0.660 to 6.599 MΩ 0.001 MΩ ±(2.0% m.v. + 5 digits)
    6.60 to 66.00 MΩ 0.01 MΩ ±(3.5% m.v. + 5 digits)

    Capacitance measurement

    Range Resolution Accuracy
    0.0 to 6.599 nF 0.001 nF ±(3.0% m.v. + 30 digits)
    6.60 to 65.99 nF 0.01 nF ±(3.0% m.v. + 10 digits)
    66.0 to 559.9 nF 0.1 nF ±(3.0% m.v. + 30 digits)
    6.600 to 59.999 µF 0.001 µF ±(3.0% m.v. + 10 digits)
    66.00 to 659.99 µF 0.01 µF
    660 to 659.999 µF 0.100 µF
    0.660 to 6.600 mF 0.001 mF

    Frequency measurement

    Range Resolution Accuracy
    10 to 65.99 Hz 0.01 Hz ±(0.1% m.v. + 5 digits)
    66.0 to 659.9 Hz 0.1 Hz
    0.660 to 6.599 kHz 0.001 kHz
    6.60 to 65.99 kHz 0.01 kHz
    66.0 to 659.9 kHz 0.1 kHz
    0.660 to 1.000 MHz 0.001 MHz

    Temperature measurement

    Range Resolution Accuracy
    -20 to 0°C 1°C ±(2.0% m.v. + 3°C)
    0 to 399°C ±(1.0% m.v. + 2°C)
    400 to 1,000°C ±(2.0% m.v. + 3°C)
    -4 to 31°F 1°F ±(2.0% m.v. + 6°F)
    32 to 749°F ±(1.0% m.v. + 4°F)
    750 to 1832°F ±(2.0% m.v. + 6°F)

     

    Duty cycle measurement

     

    ange Resolution Accuracy
    5 to 95% 0.1% ±(2.0% m.v. + 10 digits)

    „m.v.”- measured value